IEC 60811-508:2012 gives the procedure for a pressure test at high temperature, which typically applies to thermoplastic compounds used for insulating and sheathing materials. IEC 60811-508:2012 cancels and replaces Clause 8 of IEC 60811-3-1:1985, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. Significant technical changes with respect to the previous edition are as follows:
 – re-statement of oven characteristics, especially relating to anti-vibration and to temperature control;
 – enhanced detail as to the preparations and testing of flat cables;
 – enhanced detail as to thickness and dimensional measurements. See also the Foreword to IEC 60811-100:2012.  
This publication is to be read in conjunction with IEC 60811-100:2012.
Product Details
- Edition:
 - 1.0
 - Published:
 - 03/13/2012
 - Number of Pages:
 - 36
 - File Size:
 - 1 file , 630 KB
 - Note:
 - This product is unavailable in Ukraine, Russia, Belarus
 